Magnum-venus-plastech Megaject MKIV Revision 1_6 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Magnum-venus-plastech Megaject MKIV Revision 1_6. Magnum Venus Plastech Megaject MKIV Revision 1_6 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 41
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Megaject MK V Issue 1_6 Page 1 of 41
Megaject MKV
Manufacturing Technology Centre,
Chilsworthy Beam,
Gunnislake, Cornwall, PL18 9AT, UK
Tel: +44(0)1822 832621 Fax: +44(0)1822 833999
http://www.plastech.co.uk
Instruction Manual
Revision 1_6
Machine Serial Number:
SAFETY MESSAGE
All fittings, components, seals and hoses are selected and
fitted specifically to this machine to ensure that they are
compatible with the fluid materials to be used, therefore on
no account should any Magnum Venus Plastech (MVP),
factory fitted parts be replaced by non MVP components.
This is especially relevant to the catalyst fluid section. -
Stainless steel or plastic fittings MUST NOT be replaced
during a machine service with non-compatible fittings made
from inappropriate materials (such as brass), as contact
between an organic peroxide catalyst and fittings of a non
compatible material can cause a violent reaction and
explosion.
Zobrazit stránku 0
1 2 3 4 5 6 ... 40 41

Shrnutí obsahu

Strany 1 - Megaject MKV

Megaject MK V Issue 1_6 Page 1 of 41 Megaject MKV Manufacturing Technology Centre, Chilsworthy Beam, Gunnislake, Cornwall, PL18 9AT, UK Tel: +

Strany 2 - Contents

Megaject MK V Issue 1_6 Page 10 of 41 3. Recirculation Switch. Turn to right to run the machine in recirculation mode (‘on’). Turn to

Strany 3 - Megaject Mk V Overview

Megaject MK V Issue 1_6 Page 11 of 41 16. Machine Pull ‘On’ Switch Activates the machine. Deactivates in the event of either the emergency stop butto

Strany 4 - Injection Head

Megaject MK V Issue 1_6 Page 12 of 41 Commissioning & Set Up Procedures CAUTION Overalls and eye protection must be worn at all time

Strany 5 - Recirculation Valve Positions

Megaject MK V Issue 1_6 Page 13 of 41 6. Ensure both resin recirculation valves are in the recirculation position. Turn recirculation sw

Strany 6 - Machine Guards

Megaject MK V Issue 1_6 Page 14 of 41 7. If MPG system is fitted, adjust preset regulator until preset level gauge reads 2 bar. 8. Ensure both res

Strany 7 - Solvent Pump NEW SP3

Megaject MK V Issue 1_6 Page 15 of 41 Filling/Refilling Solvent Tank Sufficient solvent levels are essential for the correct flushing of the machi

Strany 8

Megaject MK V Issue 1_6 Page 16 of 41 Setting Mix Ratios Megaject catalyst levels can be adjusted by movement of the secondary pump along the ratio

Strany 9 - Operating Controls

Megaject MK V Issue 1_6 Page 17 of 41 Recirculating & Repriming Recirculating Recirculation of the machine should be carried out on a

Strany 10

Megaject MK V Issue 1_6 Page 18 of 41 Injecting and Flushing This procedure should be followed each time an injection or series of injections a

Strany 11

Megaject MK V Issue 1_6 Page 19 of 41 Note: Pump pressure and MPG preset level (if fitted) can be adjusted during injection to optimise the injecti

Strany 12 - Procedure (Epoxy)

Megaject MK V Issue 1_6 Page 2 of 41 Contents 1. Megaject MK V Overview Introduction Injection Head Machine Front Guard Catalyst System Solvent Tan

Strany 13 - Procedure (Polyester)

Megaject MK V Issue 1_6 Page 20 of 41 Optimising output Maximum output rate is dependant on various factors when pumping resin systems.

Strany 14

Megaject MK V Issue 1_6 Page 21 of 41 Shutdown Instructions Procedure 1. At the end of the day/shift switch off the machine air and leave

Strany 15 - Procedure

Megaject MK V Issue 1_6 Page 22 of 41 Maintenance The Megaject RTM Machine range has proved to be extremely reliable in service. To ma

Strany 16 - Setting Mix Ratios

Megaject MK V Issue 1_6 Page 23 of 41 Replacing Resin Pump Seals Important Safety Note All maintenance work on the machine must be carried out with

Strany 17 - Repriming

Megaject MK V Issue 1_6 Page 24 of 41 Resin pump service. In order to service internal resin pump seals first pump out any resin from internals b

Strany 18 - Injecting and Flushing

Megaject MK V Issue 1_6 Page 25 of 41 Replacing Catalyst Pump Seals (Polyester option only) See drawings 22042 Procedure 1. Remove catalyst pump f

Strany 19 - Flushing

Megaject MK V Issue 1_6 Page 26 of 41 20cc Pump Piston Seal To access the pump piston seal or any other pump internal parts proceed as follows. P

Strany 20 - Optimising output

Megaject MK V Issue 1_6 Page 27 of 41

Strany 21 - Shutdown Instructions

Megaject MK V Issue 1_6 Page 28 of 41 50CC Pump DRAWING 22301 50 CC pump assy WORDS HERE

Strany 22 - Maintenance

Megaject MK V Issue 1_6 Page 29 of 41 Servicing Injection Head (Epoxy) See drawing 22018 Note: During maintenance ensure resin and catalyst r

Strany 23 - Replacing Resin Pump Seals

Megaject MK V Issue 1_6 Page 3 of 41 Megaject Mk V Overview Introduction This manual covers the operating and maintenance instructions of your par

Strany 24

Megaject MK V Issue 1_6 Page 30 of 41 Servicing Injection Head (Polyester) See drawing 22015 Note: During maintenance ensure resin and catalys

Strany 25

Megaject MK V Issue 1_6 Page 31 of 41 Optional Auto Catalyst Valve for Phenolic Procedure 1. Remove automatic catalyst recirculation valve and NR

Strany 26

Megaject MK V Issue 1_6 Page 32 of 41 3. NRV 2 may be unscrewed from the side port after removing 6 mm clear pipe at union (0665) 4. To remove N

Strany 27

Megaject MK V Issue 1_6 Page 33 of 41

Strany 28 - WORDS HERE

Megaject MK V Issue 1_6 Page 34 of 41 Optional RAV Resin Auto Valve Caution Note. For safety reasons - Always ensure that the Resin Auto Valve

Strany 29

Megaject MK V Issue 1_6 Page 35 of 41 Mixer Tubes See drawing 22020 Mixer tubes will only require replacement if partial or full gellation/sediment

Strany 30

Megaject MK V Issue 1_6 Page 36 of 41 Catalyst Overpressure Valve (Polyester option only) See drawing 22021 Under normal operational circumstance

Strany 31

Megaject MK V Issue 1_6 Page 37 of 41 Solvent Pump See drawing 22036 Warning: Before commencing any work on the solvent system, ensure that the work

Strany 32

Megaject MK V Issue 1_6 Page 38 of 41 Appendices Mould Pressure Guard (MPG) A fluid pump driven by a piston type air motor will deliver an amplifi

Strany 33

Megaject MK V Issue 1_6 Page 39 of 41 CATAL Catalyst Monitoring System The CATAL catalyst monitoring system provides a visual/audible indication of

Strany 34

Megaject MK V Issue 1_6 Page 4 of 41 Injection Head 1. Resin recirculation valves. Swap the resin streams between the injection and the recircul

Strany 35 - Resin and Catalyst Pipework

Megaject MK V Issue 1_6 Page 40 of 41 Resin Heaters Important Note It is essential that resin heaters are not left turned on with stationary resin

Strany 36 - Machine Air Circuit

Megaject MK V Issue 1_6 Page 41 of 41 Revision History Revision codes appear on the front page of the manual. e.g. Sprint1_0 Sprint = Machine Na

Strany 37 - Solvent Pump

Megaject MK V Issue 1_6 Page 5 of 41 Recirculation Valve Positions

Strany 38 - Appendices

Megaject MK V Issue 1_6 Page 6 of 41 Machine Guards 1. Main Pump Guards. The moving mechanical parts of the machine are guarded to prevent any

Strany 39 - Operation

Megaject MK V Issue 1_6 Page 7 of 41 Solvent Pump NEW SP3 Note. With the introduction of the new Stainless Steel SP3 Solvent Pump System on models

Strany 40 - Important Note

Megaject MK V Issue 1_6 Page 8 of 41 SP3 Assembly

Strany 41 - Revision History

Megaject MK V Issue 1_6 Page 9 of 41 Operating Controls Note: Some options may not appear on your machine 1. Incoming Air Pressure Gauge. Indicate

Komentáře k této Příručce

Žádné komentáře